Availability: | |
---|---|
Quantity: | |
The HW-AC100 microwave induction module uses a planar antenna to transmit and receive high-frequency electromagnetic waves based on the Doppler effect principle, and then detects a small movement change in the return wave, and then triggers the microprocessor to work. Finally, the AC relay makes the 220v / L guide Pass band AC load circuit to 220v / N.
Professional flat micro-strip antenna design, field-shaped signal transmission and reception, wide coverage, high consistency, low power consumption, ROHS environmental protection, and strong anti-interference ability, not affected by temperature, humidity, airflow, dust, noise, light and dark, etc. .
When this product is used indoors, the sensing effect is better; when it is used outdoors, the sensing distance is slightly reduced or the sensitivity is weak due to the influence of the environment. This is a normal phenomenon, and users do not have to question the product.
Model | HW-ACHB100 | V.01version | 10.525G fixed frequency module |
Input voltage VCC | 220V-China | Note for special country power supply | Red-L, Black-N, |
load | AC 250V/8A | 10W-2000W | |
output method | AC -L ON/OFF | L-OUT/Relay L-sw | Yellow- AC L-K-OUT, Green-N |
Fuse NTC | JK250/600 | 5D-7 | |
VDR | 07D471 | ||
Induction method | Doppler motion detection (SENSOR installation is not movable) | ||
Induction distance | SENS:10m-35m | 1-2 DIP switch adjustment | Refer to catalog picture |
Induction Time | Time:can adjust 10s-30min | 3-4-5 DIP switch adjustment | Refer to catalog picture |
Photosensitive adjustment | CDS:10lux-500lux | 6-7-8 DIP switch adjustment | Refer to catalog picture |
Trigger method | Repeatable trigger (default) | ------------------ | Non-repeatable triggering is not supported |
Radiation frequency | 10.525GHz±5MHz | ||
Transmit power | <0.3W | -30dB | |
Angel | 90°-360° | Angle is determined by space | SENS determines signal strength |
Light sensor | HW-5p-1 light sensor | When receiving light, block OUT | Light sensor (default) |
Operating temperature | -20~+80℃ | Ambient temperature | |
Dimensions | L63 X M58 X 45mm | Outdoor waterproof case IP65 | Length-width-height / mm |
port | Red-L, Black-N, Yellow-OUT, Green-N | Cable length 100mm | Please standardize the wiring |
Default repeatable trigger: If the trigger signal is triggered again in the sensing area after the first trigger, the module delay time will be superimposed again when the first trigger time is not stopped (such as: the module trigger time is 2S, and it will be accepted again within 2S) To the induction signal, superimpose 2S again, and there will always be an output signal when triggering continuously. Non-triggerable triggering: Inductive trigger once, no time superimposed (such as: time 2s, trigger once, output 2s, within 2s) Regardless of multiple triggers are considered invalid, the time is not superimposed and maintained for 2s.
As shown in the figure, for AC100, the red wire is connected to 220v / L, the black wire is connected to 220v / N, the green wire is connected to one end of the AC load, and the yellow wire is connected to the other end of the AC load. The sensor will be in the working state. The internal relay K will conduct the RL (LOAD) circuit to N, so that the light bulb is in a light-emitting state. If you need to adjust the distance and time, you need to power off first, and then adjust the adjustable resistor on the back of the module according to regulations.