Humidity Sensor HR002

Short Description:

1. Product introduction: The product is called resistance type polymer humidity sensor (HR002) and it is a new type of humidity sensor. It has the characteristics of wide sensing range, fast response, high sensitivity, good water resistance, stable and reliable performance, and good consistency. 2 Appearance Size, as shown in Figure 1, Figure 2: (with) 3. Scope of Application: Electronics, textiles, warehousing, tobacco, pharmaceuticals, meteorology and other industries; Temperature and humid...


  • FOB Price: US $0.5 - 9,999 / Piece
  • Min.Order Quantity: 100 Piece/Pieces
  • Supply Ability: 10000 Piece/Pieces per Month
  • Port: Shenzhen
  • Payment Terms: L/C,D/A,D/P,T/T
  • Product Detail

    Product Tags

    1. Product introduction:

    The product is called resistance type polymer humidity sensor (HR002) and it is a new type of humidity sensor. It has the characteristics of wide sensing range, fast response, high sensitivity, good water resistance, stable and reliable performance, and good consistency.

    2 Appearance Size, as shown in Figure 1, Figure 2: (with)

    3. Scope of Application:

    Electronics, textiles, warehousing, tobacco, pharmaceuticals, meteorology and other industries;

    Temperature and humidity tables, humidifiers, dehumidifiers, air conditioners, microwave ovens and other products.

    4. Model specifications:

    HR002+, characteristic impedance 31KΩ; HR002-, characteristic impedance 23KΩ;

    5. Electrical performance:

    Rated voltage: 1.5V AC (MAX, sine wave);

    Rated power: 0.2mW (MAX, sine wave);

    operating frequency: 50Hz-2000Hz;

    working temperature: 0 °C -60 °C;

    working humidity: 20% – 95% RH;

    Temperature characteristics: 0.5%RH/°C

    hysteresis hysteresis: 2% RH;

    Response time: moisture absorption, 15S; dehumidification 25S;

    Stability: 2% RH/year;

    Humidity detection accuracy: ≤±5%RH;

    Relative humidity impedance characteristics: (25°C, 1KHZ, AC1V, sine wave), as shown in the drawing.

    Special note: when the humidity sensor is used in high humidity at 85-120°C, it is required to mark the component under high humidity, and the protective case needs special production.

    6. Standard verification conditions:

    In the atmosphere, the temperature is 25°C, the measured frequency is 1KHZ, and the measured voltage is IVAC (sine wave);

    Make sure to use AC bridge (LCR) when testing, and do not use DC power supply;

    Use split-type humidity generator (HX-1 type);

    Measurement line: 1-core shielded wire.

    Avoid hard objects or fingers touching the surface of components to avoid scratching or staining the wet film;

    Avoid testing under salt spray, corrosive gases, strong acids, strong bases, organic solvents, alcohol, acetone, etc.

    Welding conditions (180°C, 3S) For welding, use a low-temperature soldering iron or use tweezers for protection.

    Recommended Storage Conditions: Temperature 10°C40°C, Humidity: 20%RH-90%RH.

    7.Stability Test:

    The specification value is based on the 60%RH humidity change amount; after each test is completed, it should be placed in the normal air of normal temperature and humidity for 24 hours and tested after recovery. The test data are listed in the table.   

     

    1Exported feet  2Substrates  3Carbon Electrodes  4Sensitive Wet Film

    Figure 1 (1008) dimensions

    Table 1 Humidity Impedance Characteristics Table at 0°C to 60°C (31KΩ)

     0℃  5℃ 10℃ 15℃ 20℃ 25℃ 30℃ 35℃ 40℃ 45℃ 50℃ 55℃ 60℃
    20%RH 2290 1759 1351 1027 780 591 448 359 288 227
    25%RH 2100 1620 1250 935 700 539 415 328 260 218 183 149
    30%RH 1543 1175 874 650 498 382 302 238 198 165 143 124 94
    35%RH 832 612 465 353 277 217 180 150 128 109 90.4 75 61.8
    40%RH 443 335 260 202 165 135 114 97 81.2 68 59.5 52 43.6
    45%RH 248 190 153 123 105 90 76.5 65 55.6 47.5 41.9 37 31.3
    50%RH 146 115 98.9 85 72 61 52.4 45 39.1 34 30.1 26.7 22.7
    55%RH 94 80 68.1 58 49.9 43 37.1 32 28 24.5 21.9 19.5 15.6
    60%RH 64.3 56 48.2 41.5 35.9 31 26.6 22.9 20.2 17.8 15 12.6 10
    65%RH 45.9 41 35.1 30 25.9 22.3 19.2 16.5 13.8 11.6 9.6 7.9 6.45
    70%RH 33.4 30 25.6 21.9 18.7 15.9 13.1 10.8 9 7.5 6.2 5.13 4.29
    75%RH 24.4 21.5 18.3 15.6 12.8 10.5 8.69 7.2 5.95 4.92 4.13 3.46 2.84
    80%RH 17.4 15.3 12.6 10.3 8.5 7.03 5.8 4.78 3.98 3.31 2.73 2.25 1.88
    85%RH 12 10.2 8.4 6.91 5.67 4.65 3.86 3.2 2.65 2.19 1.81 1.49 1.24
    90%RH 7.9 6.87 5.6 4.56 3.77 3.11 2.56 2.11 1.74 1.44 1.19 0.99 0.82

     

    Figure 2 humidity impedance characteristics (31KΩ)

     

    Table 2 0°C to 60°C (23KΩ) Humidity Impedance Characteristics Data Sheet

     0℃  5℃ 10℃ 15℃ 20℃ 25℃ 30℃ 35℃ 40℃ 45℃ 50℃ 55℃ 60℃
    20%RH 1699.0 1305.1 1002.4 762.0 578.7 438.5 332.4 266.4 213.7 168.4
    25%RH 1558.1 1201.9 927.4 693.7 519.4 399.9 307.9 243.4 192.9 161.7 135.8 110.5
    30%RH 1144.8 871.8 648.5 482.3 369.5 283.4 224.1 176.6 146.9 122.4 106.1 92.0 69.7
    35%RH 617.3 454.1 345.0 261.9 205.5 161.0 133.5 111.3 95.0 80.9 67.1 55.6 45.9
    40%RH 328.7 248.5 192.9 149.9 122.4 100.2 84.6 72.0 60.2 50.5 44.1 38.6 32.3
    45%RH 184.0 141.0 113.5 91.3 77.9 66.8 56.8 48.2 41.3 35.2 31.1 27.5 23.2
    50%RH 108.3 85.3 73.4 63.1 53.4 45.3 38.9 33.4 29.0 25.2 22.3 19.8 16.8
    55%RH 69.7 59.4 50.5 43.0 37.0 31.9 27.5 23.7 20.8 18.2 16.2 14.5 11.6
    60%RH 47.7 41.5 35.8 30.8 26.6 23.0 19.7 17.0 15.0 13.2 11.1 9.3 7.4
    65%RH 34.1 30.4 26.0 22.3 19.2 16.5 14.2 12.2 10.2 8.6 7.1 5.9 4.8
    70%RH 24.8 22.3 19.0 16.2 13.9 11.8 9.7 8.0 6.7 5.6 4.6 3.8 3.2
    75%RH 18.1 16.0 13.6 11.6 9.5 7.8 6.4 5.3 4.4 3.7 3.1 2.6 2.1
    80%RH 12.9 11.4 9.3 7.6 6.3 5.2 4.3 3.5 3.0 2.5 2.0 1.7 1.4
    85%RH 8.9 7.6 6.2 5.1 4.2 3.5 2.9 2.4 2.0 1.6 1.3 1.1 0.9
    90%RH 5.9 5.1 4.2 3.4 2.8 2.3 1.9 1.6 1.3 1.1 0.9 0.7 0.6

     

     

    Figure 3 Humidity Impedance Characteristic Diagram (23KΩ)

     

     

     